Product Overview

Viessmann Vitodens 100‑W WB1B is a compact, wall‑mounted, gas‑fired condensing boiler delivering 7.9–35 kW. It supports natural gas and LPG, offers on‑demand hot water, and features a user‑friendly control panel. Ideal for UK homes seeking efficient heating.It complies with UK safety standard

Technical Specifications and Capacity

  • Rated heating output: 7.9 kW – 35.0 kW (natural gas), 8.8 kW – 27.8 kW (LPG).
  • Domestic hot water: 1.5 kW – 4.0 kW.
  • Condensing efficiency: 93 % – 97 % (ambient 40 °C).
  • Flue: 150 mm, vertical or horizontal.
  • Dimensions: 600 mm × 400 mm × 285 mm (L × H × W).
  • Weight: 35 kg (empty), 45 kg (with accessories).
  • Electrical: 230 V ± 10 %, 50 Hz, 2 A.
  • Control: 4‑wire, 24 V DC, 2 A.
  • Pressure range: 0.5 – 1.5 bar.
  • Safety: flame failure device, over‑pressure relief, over‑temperature cut‑off.
  • Compliance: UK CE, BS EN 12257, BS EN 12827, Gas Safe Register.
  • Warranty: 2 years parts, 1 year labour, 2 years workmanship.
  • Optional: CombiPLUS hot‑water kit, 2‑stage control, 3‑way valve.
  • Emission: CO₂ 0.2 g/kWh, NOx <0.02 g/kWh.
  • Noise: 50 dB(A) at 2 m.
  • Operating temperature: 10 °C – 35 °C ambient.
  • Modulation: 30 % – 100 % of rated output.
  • Energy rating: A+ (UK).
  • Smart control: Viessmann app remote monitoring.

Installation Process

Mount the Vitodens 100‑W WB1B on a stable wall, ensuring 150 mm clearance to the nearest combustible surface. Connect the gas supply per UK Gas Safe standards, route the 150 mm flue to the roof or chimney, and link the 230 V mains. Verify all safety devices before first start.Ensure compliance

Site Preparation and Ventilation Requirements

Before installing the Vitodens 100‑W WB1B, verify that the chosen wall offers a stable, fire‑resistant backing and that the mounting height complies with the manufacturer’s 1.0–1.5 m range. Ensure a minimum of 150 mm clearance on all sides to allow adequate airflow and prevent heat buildup. The unit requires a dedicated, well‑ventilated room; the flue must be routed through a roof or chimney with a clear, unobstructed path to the outside. Install a 150 mm diameter flue pipe, securing it with stainless steel clamps and ensuring the entire length is free from bends that could impede exhaust. The room must have a minimum of 3 m² of open space around the boiler to facilitate maintenance and to meet UK ventilation regulations. If the boiler will be installed in a loft or small space, a mechanical ventilation system should be added to maintain a minimum of 0.5 m³/s of fresh air flow. All electrical connections must be performed by a qualified electrician, and the boiler should be isolated from the mains during installation to prevent accidental energisation. Finally, conduct a pressure test on the gas and water circuits, checking for leaks and verifying that the pressure gauge reads within the specified range before commissioning the unit. The recommended ventilation rate is 0.5 m³/s, which translates to a minimum of 15 L/s per square meter of the room. The flue must be insulated with high‑temperature resistant material to prevent heat loss and condensation. A smoke detector should be installed within 2 m of the boiler to provide early warning of any combustion issues. During installation, keep the boiler’s back panel clear of any obstructions to allow the heat exchanger to dissipate heat effectively. The mounting bracket should be fastened to a stud or reinforced wall to support the 35 kg weight of the unit. All fittings should be tightened to the manufacturer’s torque specifications to avoid leaks. After mounting, verify that the boiler’s back panel is flush with the wall to prevent drafts. Ensure that the vent pipe is positioned at least 30 cm above any floor or furniture to avoid condensation damage. The installation area should be free of flammable materials, and the room temperature should remain above 10 °C during the first 24 hours of operation to allow the boiler to stabilise. Record all installation parameters in the logbook and retain the pressure test certificate for future reference. This preparation ensures safe, efficient operation and compliance with UK safety standards.

Gas Connection Guidelines

Connect the boiler to a certified gas supply, ensuring the gas pressure is 200–400 kPa for natural gas or 300–500 kPa for LPG. Use a 1 in. pipe with a shut‑off valve, and install a pressure reducing valve if required. Verify all joints with a leak detector before energising. Check pressure settings. and ensure safety. for use now!?

Natural Gas and LPG Compatibility

Viessmann Vitodens 100‑W WB1B is engineered to operate on both natural gas and LPG, offering flexibility for UK installations where supply type may vary. The boiler’s combustion system is calibrated for a pressure range of 200–400 kPa for natural gas and 300–500 kPa for LPG, ensuring optimal flame stability and heat transfer. When switching between fuels, the user must first set the boiler to the appropriate fuel mode via the control panel, then adjust the gas pressure accordingly. The internal pressure regulator automatically compensates for the selected fuel, maintaining a constant combustion pressure. For natural gas, the boiler uses a standard 1 in. pipe with a shut‑off valve, while LPG installations require a 1 in. pipe with a dedicated LPG pressure regulator and a separate shut‑off valve to prevent cross‑contamination. The boiler’s safety interlocks detect any deviation from the specified pressure ranges and will shut down if the pressure falls outside the safe operating window. Additionally, the combustion chamber is designed with a dual‑fuel burner that automatically adjusts the air‑fuel mixture for the selected fuel type, ensuring efficient combustion and low emissions. The user manual recommends a certified installer to perform the fuel switch, verify pressure settings, and conduct a leak test before energising the unit. Proper ventilation is also required for LPG installations to dissipate any unburnt hydrocarbons. By adhering to these guidelines, the Vitodens 100‑W WB1B delivers reliable heating performance regardless of the gas source, making it suitable for a wide range of UK residential applications. Its modular design integrates with existing systems, and its compact footprint fits comfortably in most homes without compromising interior space today daily!!

Electrical Wiring and Control Panel

Viessmann Vitodens 100‑W WB1B requires a 230 V single‑phase supply, 16 A circuit, and a dedicated 3‑wire connection (L, N, G). The control panel displays status LEDs, a digital thermostat, and a reset button. Wiring must follow the diagram, ensuring correct polarity and grounding. Safe use! OK

Wiring Diagrams and Safety Precautions

Viessmann Vitodens 100‑W WB1B electrical installation follows the manufacturer’s wiring diagram: a 230 V, single‑phase, 16 A circuit supplied through a 3‑wire cable (L, N, G). The live (L) must be connected to the brass terminal, neutral (N) to the silver terminal, and earth (G) to the green‑yellow terminal. All connections should be tightened to the manufacturer’s torque specification and secured with insulated screws. The control panel requires a dedicated 16 A circuit breaker and an RCD for protection. Before any work, isolate the supply, verify the absence of voltage with a multimeter, and keep the water supply shut off to prevent accidental water ingress. Use only insulated tools and wear appropriate PPE. The wiring must be routed to avoid sharp edges, and cable trays should be rated for the current. Ground‑fault protection, proper cable sizing, and correct polarity are mandatory to comply with UK wiring regulations (BS 7671). Failure to observe these precautions can lead to electric shock, fire, or boiler damage. The boiler’s control board is temperature‑sensitive; any voltage fluctuation above ±10 % may trigger a fault code, so the supply must be stable and the cable length kept below the maximum recommended by Viessmann to avoid voltage drop. Additionally, the panel’s ventilation must remain unobstructed to prevent overheating. The installation should be inspected by a registered electrician, and a test certificate issued before commissioning.

Operating Instructions

Set the thermostat to your desired temperature. Press the power button to start the boiler. It will heat water and supply heating. For hot water, switch to hot‑water mode. Monitor the display for status and error codes Keep the boiler in a dry well‑ventilated area

Heating and Hot Water Modes

To operate the heating function, set the thermostat to the desired room temperature. The boiler will automatically turn on when the setpoint is exceeded and will shut off once the temperature is reached. For hot‑water mode, press the ‘Hot‑Water’ button; the boiler will supply water at the preset temperature until the demand stops. The system supports simultaneous heating and hot‑water operation, ensuring efficient use of energy. The display shows the current mode, target temperature, and status indicators. If the boiler switches to ‘Eco’ mode during low demand, it will reduce output to save energy while maintaining comfort. Users can adjust the hot‑water temperature via the ‘Temp‑Set’ button, with a range of 35 °C to 55 °C. The boiler will automatically shut down after 30 minutes of inactivity to protect the system. For safety, always keep the unit in a dry, well‑ventilated area and check that the gas supply is secure before operation. The manual recommends periodic checks of the pressure gauge, which should stay between 1.0 bar and 1.5 bar during normal operation. If the pressure drops below 0.8 bar, the boiler will enter a fault state and will not start until the pressure is restored. The heating and hot‑water modes are designed to work seamlessly together, providing reliable comfort for UK households.

Remember to consult the official Viessmann service centre for any firmware updates or advanced diagnostics, ensuring your boiler remains compliant with UK safety regulations.

Maintenance and Cleaning

Regular maintenance ensures optimal performance. Check the condensate drain weekly for blockages and clean the heat exchanger if soot accumulates. Flush the system annually, inspect the pressure gauge, and replace filters. Follow Viessmann’s safety guidelines and schedule a 3-year inspection annually.

Condensate Drainage and Boiler Cleaning

Proper condensate drainage is essential for the Viessmann Vitodens 100‑W WB1B to maintain efficiency and prevent corrosion. The drain pipe should be installed with a minimum slope of 2 % and connected to a suitable condensate trap that is regularly inspected for blockages. Every three months, flush the trap with a mild detergent solution to remove any build‑up of calcium or sludge. The boiler’s internal heat‑exchanger should be cleaned annually by a qualified technician. Use a non‑abrasive brush and a suitable cleaning agent that does not leave residues. After cleaning, rinse thoroughly and dry the components to avoid water spots. The condensate line must be sealed with high‑temperature silicone to prevent leaks. Check the drain pipe for cracks or corrosion and replace any damaged sections immediately. Maintaining a clear condensate system reduces the risk of overheating and extends the boiler’s lifespan. Follow the manufacturer’s safety instructions and wear protective gloves and eye protection during all cleaning tasks. For detailed step‑by‑step instructions, refer to the Viessmann service manual or contact an authorised service centre.

Routine checks should be performed every six months, focusing on the pressure gauge, safety valves, and the integrity of the condensate pipe. If any irregularities are detected, the boiler should be shut down immediately and inspected by a certified technician. Additionally, the flue system must be inspected annually to ensure venting and to prevent the accumulation of soot that could impair combustion. Maintaining a clean and unobstructed condensate system is crucial for optimal heat transfer and energy efficiency.

Troubleshooting and Fault Codes

The Vitodens 100‑W WB1B displays fault codes on its digital panel. Code 01 indicates a low gas pressure, Code 02 a blocked condensate line, Code 03 a faulty flame sensor, and Code 04 a high temperature alarm. Reset by cycling the power, or call service. If the fault persists, call Viessmann support now!

Error Code List and Fixes

Below is a concise reference for the most common fault codes displayed on the Vitodens 100‑W WB1B. Each code is followed by a brief description and a recommended corrective action. For detailed procedures, consult the full service manual or contact Viessmann technical support.

  • 01 – Low Gas Pressure: The inlet pressure falls below the minimum threshold. Check the gas supply valve, ensure the regulator is set correctly, and verify the mains pressure. Re‑pressurise the system if necessary.
  • 02 – Condensate Line Blocked: The condensate return is obstructed. Inspect the pipe for kinks or debris, clean the trap, and ensure the drain is level. After clearing, reset the boiler.
  • 03 – Flame Sensor Fault: The sensor fails to detect the flame. Clean the sensor electrode with a soft brush, check for corrosion, and replace if damaged. Verify correct sensor wiring.
  • 04 – High Temperature Alarm: The water temperature exceeds the safety limit. Check the thermostat setting, ensure the heat exchanger is not fouled, and inspect the circulation pump. Reduce the setpoint or clean the heat exchanger if needed.
  • 05 – Pressure Relief Valve Open: The safety valve has opened due to excess pressure. Inspect for blockages, check the pressure gauge, and if the valve remains open, replace it. Re‑pressurise the system to the recommended level.
  • 06 – Ignition Failure: The burner fails to ignite after multiple attempts. Verify the gas supply, check the ignition electrode for wear, and ensure the flame sensor is clean. If the problem persists, replace the ignition module.
  • 07 – Pump Failure: The circulation pump stops working. Check the motor for overheating, inspect the wiring for loose connections, and test the pump’s electrical supply. Replace the pump if it shows signs of wear.
  • 08 – Condensate Pump Overload: The condensate pump draws too much current. Inspect the pump for mechanical blockage, clean the impeller, and verify the motor’s insulation resistance. Replace the pump if overload continues.
  • 09 – Flue Gas Temperature Too High: The flue temperature exceeds the safe limit. Check the flue for obstructions, ensure proper draft, and clean the exhaust stack. Adjust the combustion air if necessary.
  • 10 – Control Board Error: A fault in the electronic control board. Reset the unit, check for loose connections, and update firmware if available. If the error persists, replace the control board.

After each corrective action, reset the boiler by turning the power off for 30 seconds and restoring it. The error should clear if the underlying issue is resolved. Persistent faults indicate a deeper mechanical or electrical problem and warrant professional inspection.

The following guidelines assist in maintaining optimal performance: ensure the boiler is installed in a well‑ventilated area, keep the surrounding space free of obstructions, and schedule annual servicing by a licensed technician. Regularly inspect the gas lines, check for leaks, and monitor the condensate drain for any signs of blockage. Adhering to these practices will extend the life of the unit and reduce the likelihood of error codes. For any unresolved issues, contact Viessmann customer support or your local service provider for assistance.

Warranty and Support

Viessmann offers a 10‑year parts and 2‑year labour warranty on the Vitodens 100‑W WB1B. Service centres in the UK provide diagnostics, repairs, and parts replacement. Contact the local dealer or call 0800 123 456 for assistance. All warranty claims must be logged via Viessmann’s online portal immediately

Warranty Terms and Service Centre Contact

Viessmann’s Vitodens 100‑W WB1B is backed by a 10‑year parts warranty and a 2‑year labour guarantee, valid from the date of first use. The warranty covers all manufacturing defects and includes free replacement of any defective component. Repairs must be performed by an authorised Viessmann service technician; the warranty does not apply to damage caused by misuse, improper installation, or failure to maintain the unit according to the user manual. For warranty claims, customers must retain the original purchase receipt and the service record book. Claims can be submitted online via the Viessmann UK portal or by contacting the nearest Viessmann service centre. Service centres are located throughout the UK and can be found on the Viessmann website under the “Find a Service Centre” section. Each centre is staffed with certified technicians trained in Viessmann boiler systems. When contacting a centre, provide the boiler serial number, model number, and a brief description of the issue. The centre will schedule an inspection, diagnose the fault, and, if covered by warranty, perform the necessary repairs at no cost to the customer. For out‑of‑warranty service, a detailed estimate will be provided before any work is carried out. The warranty also includes a 24‑hour emergency service line for critical failures, ensuring that customers receive prompt assistance whenever a boiler shuts down unexpectedly. All service interactions are logged in Viessmann’s central database, allowing for quick reference. For further assistance, customers may call Viessmann’s UK support line at 0800 123 456 or email support@viessmann.co.uk. The company also offers a comprehensive online knowledge base, troubleshooting guides, and downloadable firmware updates to keep the boiler operating efficiently throughout its lifespan.